Subzero is the embodiment of design and also performance refrigeration. It isn’t simply a device, your Subzero is an essential element of your excellent kitchen. It makes sense that you wouldn’t wish to trust your fridge to just any type of device fixing firm. You want a group of Subzero fridge repair work specialists that can shield your investment while offering the premium service you are entitled to.
It Is Fixed Device Repair work is the firm you must trust with all of your Subzero repair needs. Our specialists concentrate on Subzero service so you can rely on that we have the skills to get the job done right.
HOW TO USE THE MISTAKE CODE TROUBLESHOOTING OVERVIEW
Error Codes indicate issues registered by particular parts. If mistake codes are registered, they will certainly appear prior to temperature analyses while in Diagnostic Mode.
KEEP IN MIND: If Error Codes appear with a flashing «SERVICE» annunciator before launching Diagnostic Mode, the device experienced excessive compressor run condition that may or might not be connected with the Error Codes displayed
To initiate Diagnostic Mode, press as well as hold either COLDER key, after that push the POWER secret, after that launch both tricks. Now, check to see if Mistake Codes are present, being sure to toggle through all error and temperature analyses by pushing either COLDER vital or either WARMER key. (See Mistake Code Table Below).
If Error Codes show up during Diagnostic Setting, follow the Mistake Code Troubleshooting Guide on the following web page. The left column of the troubleshooting overview notes the error codes. The info in the right column explains what tests to execute and/or what activity to require to remedy the mistake.
KEEP IN MIND: If mistake codes are observed in diagnostic mode, a non-flashing SOLUTION annunciator will appear on the LCD when Diagnostic Setting ends, showing mistake codes are still stored. Error Codes need to be cleared from the digital control memory by hand. To clear the non-flashing SERVICE annunciator and the mistake codes, the trouble has to be remedied and also the unit needs to be ON, after that:.
Error Code Table
CODE | INDICATION |
05 | Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
06 | Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
07 | Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
08 | Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
20 | Defrost under-heat with no voltage feedback through Gray/White wire at defrost start |
21 | Defrost overheat |
22 | No voltage feedback through Gray/White wire at defrost start |
23 | Defrost overheat with no voltage feedback through Gray/White wire at defrost start |
24 | Defrost under-heat |
30 | N/A |
40 | Excessive Freezer Compressor Run |
50 | Excessive Refrigerator Compressor Run |
Error Code | CAUSE | SOLUTION |
Error Code 11 | The refrigerator is too warm and/or the upper cabinet has been open too long | You will receive this error if your refrigerator’s upper cabinet has been open too long or if the upper cabinet is too warm. To resolve the error, disconnect the power from the unit at the circuit breaker. Leave the power off for at least one minute. Turn the power back on and keep the refrigerator door closed until the unit has reached optimal temperature. |
Error Code 05.
A. If «EE» for refrigerator compartment was shown and «SOLUTION» blinking, examine the following:.