Subzero is the embodiment of design and performance refrigeration. It isn’t just a home appliance, your Subzero is an essential element of your excellent kitchen. It makes sense that you would not want to trust your refrigerator to just any device fixing firm. You want a team of Subzero fridge repair service experts that can shield your investment while supplying the costs service you should have.
It Is Fixed Appliance Repair is the business you need to trust with every one of your Subzero repair needs. Our specialists specialize in Subzero service so you can rely on that we have the abilities to finish the job right.
HOW TO USAGE THE MISTAKE CODE TROUBLESHOOTING OVERVIEW
Mistake Codes show issues signed up by specific elements. If mistake codes are registered, they will show up prior to temperature analyses while in Diagnostic Setting.
NOTE: If Error Codes appear with a flashing «SERVICE» annunciator prior to initiating Diagnostic Mode, the system experienced extreme compressor run condition that might or might not be associated with the Error Codes presented
To initiate Diagnostic Mode, press as well as hold either COLDER trick, after that push the POWER key, then release both secrets. Currently, inspect to see if Error Codes exist, making sure to toggle via all mistake as well as temperature readings by pushing either COLDER key or either WARMER secret. (See Error Code Table Below).
If Mistake Codes show up throughout Diagnostic Setting, adhere to the Error Code Troubleshooting Guide on the adhering to page. The left column of the troubleshooting overview details the mistake codes. The info in the appropriate column explains what tests to carry out and/or what activity to take to deal with the error.
KEEP IN MIND: If mistake codes are observed in diagnostic mode, a non-flashing SOLUTION annunciator will appear on the LCD when Diagnostic Mode finishes, indicating mistake codes are still kept. Error Codes should be cleared from the electronic control memory by hand. To clear the non-flashing SERVICE annunciator as well as the error codes, the issue must be corrected as well as the system should be ON, after that:.
Error Code Table
CODE | INDICATION |
05 | Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
06 | Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
07 | Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
08 | Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
20 | Defrost under-heat with no voltage feedback through Gray/White wire at defrost start |
21 | Defrost overheat |
22 | No voltage feedback through Gray/White wire at defrost start |
23 | Defrost overheat with no voltage feedback through Gray/White wire at defrost start |
24 | Defrost under-heat |
30 | N/A |
40 | Excessive Freezer Compressor Run |
50 | Excessive Refrigerator Compressor Run |
Error Code | CAUSE | SOLUTION |
Error Code 80 | High variable speed compressor differential pressures or low voltage supplied to variable speed compressor | Inspect the suction pressure and return the suction pressure to normal levels. |
Error Code 80
A. If «EE» for refrigerator compartment was presented and also «SERVICE» flashing, check the following:.